Mircom fire alarm system
MIRCOM FIRE ALARM CONTROL UNITS 8-64 zone
Description
Mircom’s FA-1000 Series Microprocessor Based Fire Alarm Control Panels are Multi-Zone units designed for maximum flexibility and easy installation and operation. Fully configurable from the front panel using push buttons and DIP switches, the FA-1000 Series enables the user to configure the system to meet their specific requirements. With a large capacity of supervised Class A (Style D) or Class B (Style B) Initiating Circuits and supervised Class A (Style Z) or Class B (Style Y) Indicating Circuits, the FA-1000 Series is designed to meet virtually all applications.
The FA-1000 Series consists of a Main Fire Alarm Chassis which houses and controls all other modules. Additional modules may be installed to configure the system to meet any requirements that the user may have. The FA-1000 Series allows for additional Indicating Circuit, Initiating Circuit and Relay modules to be added to the system. In addition it allows for optional modules such as the UDACT-300A Digital Communicator and the PR-300 Polarity Reversal/City Tie Module.
Equipped with Configuration DIP Switches on the Main Display Module the FA-1000 Series Fire Alarm Control Panels are configured through a combination of DIP switch and button settings. Through this configuration method the user can define the system as a Single Stage or Two Stage operation as well as perform various functions such as a One Man Walk Test.
Features
• Listed to UL 864, 9th edition
• Large system capacity
• Modular design
• Each Indicating Circuit can be configured as Silenceable or Non-Silenceable
• Audibles may be configured as Steady, Temporal Code, CaliforniaCode or March Time
• Each Initiating Circuit can be configured as Alarm, Supervisory,Waterflow or Trouble
• Two LEDs per Initiating circuit; one for Trouble and one for Status
• Initiating and Indicating Circuits may be individually disconnectedby a DIP switch
• Configurable Signal Silence Inhibit, Auto Signal Silence, Two-Stage Operation and One Man Walk Test
• Subsequent Alarm, Supervisory and Trouble operation
• Two outputs for 4 wire resettable smoke power supply (200 mAMax. each)
• Auxiliary relay contacts for Common Alarm and Common Supervisory as well as a Common Trouble Relay (Each relay contact Form C,28 VDC @ 1 Amp (resistive))
• RS-485 Interface for RA-1000 Remote Multiplex Annunciators
• Interface for Remote Trouble Indicator
• Easy configuration via push buttons and DIP switches on the frontpanel
• Fully site or field programmable Indicating Circuits and AuxiliaryRelays
• Extensive Transient Protection
• Slide-in labels for zone identification
• 6 Amp or 12 Amp power supplies available
• Removable door for easy installation and servicing
• Removable terminal blocks for easy wiring and servicing